Date11th, Sep 2018

Summary:

Postnova Analytics reports on how Asymmetrical Flow Field Flow Fractionation coupled to Multi Angle Light Scattering (AF4-MALS) has been successfully used to characterize a polydisperse cellulose nanocrystal for size and thickness in just 40 minutes analysis time.

Full text:

Postnova Analytics reports on how Asymmetrical Flow Field Flow Fractionation coupled to Multi Angle Light Scattering (AF4-MALS) has been successfully used to characterize a polydisperse cellulose nanocrystal for size and thickness in just 40 minutes analysis time.

Nanocrystals research has been an area of significant interest lately, due to a growing range of applications in advanced materials, biomedical, environmental, optical and semiconductor fields. Thorough size characterization of these nanocrystals is important since their rheological and control processing properties can be affected by their size, shape and surface area.

The authors of this new study propose AF4-MALS as an alternative to bulk characterization techniques such as Transmission Electron Microscopy (TEM), Atomic Force Microscopy (AFM) and Dynamic Light Scattering (DLS). The main advantages of AF4-MALS over the bulk characterization techniques are high resolution and fast analysis time.

Due to attractive properties including low thermal expansion, optical transparency, renewability, biodegradability, low toxicity and low cost - Cellulose nanocrystals are used in a range of industrial applications. In this study a Cellulose nanocrystal sample, isolated from softwood sulphite pulp, was analyzed by AF4-MALS to measure the length and thickness of the crystals as a function of size. The cellulose nanocrystal length distribution was found to be in a good agreement with the result of the AFM analysis. Cellulose nanocrystal Rh (obtained from AF4) and R.M.S radii (obtained from MALS) were used to calculate cellulose nanocrystal thickness. The Cellulose nanocrystal thickness profile showed a broad distribution suggesting aggregation of single crystals at the larger end of the distribution.

Source: http://www.postnova.com/

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

APA

Postnova Analytics. (2018, September 11). Measuring nanocrystal length and thickness in just 40 minutes analysis time. News-Medical. Retrieved on August 22, 2022 from https://www.news-medical.net/news/20180911/Measuring-nanocrystal-length-and-thickness-in-just-40-minutes-analysis-time.aspx.

MLA

Postnova Analytics. "Measuring nanocrystal length and thickness in just 40 minutes analysis time". News-Medical. 22 August 2022. .

Chicago

Postnova Analytics. "Measuring nanocrystal length and thickness in just 40 minutes analysis time". News-Medical. https://www.news-medical.net/news/20180911/Measuring-nanocrystal-length-and-thickness-in-just-40-minutes-analysis-time.aspx. (accessed August 22, 2022).

Harvard

Postnova Analytics. 2018. Measuring nanocrystal length and thickness in just 40 minutes analysis time. News-Medical, viewed 22 August 2022, https://www.news-medical.net/news/20180911/Measuring-nanocrystal-length-and-thickness-in-just-40-minutes-analysis-time.aspx.